Discarding Criteria

Examination according to visible wire breaks - DIN 15 020 - sheet 2 transmission groups 2m - 5m

rope specifications rope-Ø / construction Number of load bearing wires Number of visible wire breaks on a length of 6 x rope-Ø Number of visible wire breaks on a length of 30 x rope-Ø
         
PAWO F3 Ø 6,5 114 6 12
  Ø 7-20 152 10 19
PAWO F7   152 13 26
PAWO F7S   152 13 26
PAWO F10 Ø 8-12 117 10 19
  Ø 13-20 144 13 26
PAWO 819W   152 13 26
PAWO 836WS   288 24 48
F819 S-FE     10 19
F819 W-FE     13 26
F819 S-FE DT     10 19
PAWO F1 6 x 19 114 10 19
  6 x 19 S 114 6 12
  6 x 19 W 114 10 19
  8 x19 S 152 10 19
  8 x19 W 152 13 26

For further surveillance the prescriptions of DIN 15 020 sheet 2 3.4 have to be observed.